Kingsman ZCVRB47/60/72
Available in 47, 60, and 72 inch sizes
STANDARD FEATURES
Adjustable heat and flame size
IPI valve system operates during power failures
Safety Screen Barrier
MEDIA
Crushed Glass (your choice of colour)
Add optional Cannonballs
OPTIONAL ACCESSORIES
Fan Kit
Heat Activated with Variable Speed Control
Light Kit
Accent Lighting Lamps (bottom)
Liner
Surrounds
Trim - narrow (4-sided) black or stainless steel
Vented Chase
For Cool Touch Walls and Reduced Mantel/TV Clearances
CONTROL METHODS
Wall Switch
On/Off
Wall Mount Thermostats
On/Off Digital
Programmable Digital 5 day (weekday) and 2 day (weekend)
Remote Controls
On/Off with Thermostat
On/Off with Thermostat & Flame Modulation
On/Off with Thermostat, Flame Modulation & Fan Speed Control
CLICK HERE FOR MORE INFO ON PRODUCT SPECS, BROCHURES & MANUALS
Tech Specs
Model
ZCVRB47NE
ZCVRB47LPE
ZCVRB60NE
ZCVRB60LPE
ZCVRB72NE
ZCVRB72LPE
Fuel
Natural
Propane
Natural
Propane
Natural
Propane
Gas Control
IPI PF1
IPI PF1
IPI PF1
IPI PF1
IPI PF1
IPI PF1
Max BTU
24500
24500
35000
35000
50000
50000
Min BTU
16500
20500
23000
28000
34000
39000
Efficiency (P.4.1-15)
57.31%
57.1%
56.66%
56.66%
53.64%
53.64%
Venting
4/7" Flex
4/7" Flex
5/8" Flex
5/8" Flex
5/8" Flex
5/8" Flex
Viewing Area
Width
Height
ZCVRB47
40-5/8"
13-7/8”
ZCVRB60
60"
17-7/8"
ZCVRB72
73-1/16”
17-7/8"
Framing Dimensions
Width
Height
Depth
ZCVRB47
47”
38-3/4”
18-1/4”*
ZCVRB60
67”
39-3/4”
19-1/4”*
ZCVRB72
79-1/8”
42”
19”*
*dependent on finishing material used
Base of Fireplace to Bottom of Viewing Area
ZCVRB47
ZCVRB60
ZCVRB72
Distance
~10"
~10"
~8-1/2"
Optional Vented Chase - Opening with no Grills
ZCVRB47
ZCVRB60
ZCVRB72
Min. Chase Opening Free Air Area
105sq/in.
200sq/in.
285sq/in.
Min. Enclosure Height (from bottom of FP)
70”
76”
79”
Min. Opening Below Ceiling
1-1/4”
1-7/8”
2-3/8”
NOTE: To vent the fireplace chase, removal of ventilation plates from the fireplace is required.
Optional Vented Chase - Opening with Grills
ZCVRB47
ZCVRB60
ZCVRB72
Min. Chase Opening Free Air Area
105sq/in.
220sq/in.
285sq/in.
Min. Enclosure Height (from bottom of FP)
70”
76”
79”
Grill Opening (Max. Distance from top of Enclosure)
2”
3/4”
3/4”
NOTE: To vent the fireplace chase, removal of ventilation plates from the fireplace is required.
Optional Vented Chase - Grill Opening Dimensions
Width
Height
Front – ZCVRB47
46-3/4”
2-5/8”
Front – ZCVRB60
60-5/8”
3-5/8”
Front - ZCVRB72
78-5/8”
3-5/8”
Sides – ZCVRB47/60
15-1/4”
6-5/8”
Sides - ZCVRB72
15-1/4”
9"
NOTE: To vent the fireplace chase, removal of ventilation plates from the fireplace is required.